100 SERIES FIRE BOX


 

The 100 Series units are our smallest Fire Boxes.  We currently manufacture two models the S-111 and the S-116.  These units are differentiated by their manifold lengths.

The S116 has an 16 foot long fire box and manifold and the S-111 has an 11 foot long fire box and manifold.

The 300 Series units are approximately 12 feet wide by 12 feet high, whereas the 200 Series units are approximately 8 feet wide and 8 feet high, and the 100 Series approximately 6 feet wide and 6 feet high.

The CAD drawings below are representative of the S-116 and S-111

Detail Specifications:  S-116    S-111

S-111E - Electric Version on Way to British West Indies

S-116 - Full Operation at Lake Tahoe, California, 2001

S-SERIES SYSTEM COMPARISON

Model

Overall Size
L × W × H

Fire Box
L × W × H

Weight
lbs

Fuel
Consumption*
gal/hr
Through-put**
tons/hr

S-327

37' 4" × 11' 10" × 9' 7" 27' 2" × 8' 5" × 8' 1"

50,000

3.5 6 - 10

S-321

31' 4" × 11' 10" × 9' 7"

21' 2" × 8' 5" × 8' 1"

46,000

3.5 5 - 8

S-220

30' 2" × 8' 6" × 8' 6"

19' 8" × 6' 2" × 7' 1"

33,500

2.5 3 - 6

S-217

27' × 8' 6" × 8' 6"

16' 5" × 6' 2" × 7' 1"

30,000

2.5

2 - 5

S-116

27' × 7' 5" × 7' 8"

16' × 5' × 6'

26,000

2.5

1 - 4
S-111 18' 11" × 7' 5" × 7' 8"

11' × 5' × 6'

21,300

2.5

0.5 - 2

United Kingdom (EU) Fire Box Models S-10 Series

 
 

Table with Metric Conversions

*) Diesel Engine Version:

S-300 Series: Kubota V3300-TE (Tier2).
S-200/S-100 Series: Kubota V2003-TE (Tier2), or equivalent engines. Diesel fuel consumption rated at average operating RPM.
Drive System: PTO & mechanical direct coupling drive.
Fuel Tank: Min. 65 Gallons.

**) Notes on Through-put:

Through-put depends on many factors, such as nature and type of wood waste, its moisture content, prescribed opacity limits, operator skills, elevation of location, etc.  The figures stated here are guidelines only.  If more specific information is required, please, contact the Factory.

Electric Motor Version
(Permanent/stationary units only):

Motor: 3-Phase, heavy-duty, with enclosed controller;
Min. 200V, max. 480V, 50Hz to 60Hz;
Drive System: PTO & mechanical direct coupling drive.

Options:

Ember Screen (retractable top firebox screen); Engine deck security guarding; Heat recovery (Permanent/stationary units only); Custom firebox designs also available.

NOTE:
1) All weights and dimensions are approximate.
2) Dimensional drawings can be provided on request.
3) Subject to change without notice.

 Rev. 12-07b

Printer Friendly Table

Previous Page
Top of Page

orline.GIF (108 bytes)

Note on Printing Information from This Web Site:
The pages of this site have not been designed for printing.  Please, go to our
DOWNLOAD or PHOTO GALLERY section or click on "Printer Friendly Version" where available for printing.


Lease-Financing
For further information, direct factory sales, price quotations
and delivery information, please, contact:

AIR BURNERS, LLC
Marketing & Sales Department
4390 Cargo Way
Palm City, Florida 34990

Regular Factory Sales Office Hours:
Monday through Thursday  7:30 am - 5:30 pm

For urgent matters after hours:
Call 561-248-9011


Norbert Fuhrmann, Sales Director
Tel:
 772-220-7303
Tel:  888-566-3900 (Toll-free, US only)
Fax: 772-220-7302

E-Mail  nfuhrmann@airburners.com

orlineV.GIF (908 bytes)

AIR BURNERS, LLC
Main Factory
4390 Cargo Way
Palm City, Florida 34990

Tel: 772-220-7303
Fax: 772-220-7302

Palm City is located 30 miles
North of West Palm Beach
on Florida's Atlantic Coast West of Stuart

Get driving directions and map (printer friendly) and airport locations
 

Driving Directions

More Driving Directions
from Mapquest:

General E-Mail
info@airburners.com

Search This Site
(Site Search Includes PDF Files)
Top of This Page
Back to Previous Page

THANK YOU FOR YOUR VISIT !


Copyright 1996-2008, Air Burners, LLC
All Rights Reserved.

The Words "Air Burners", "airburners" and the Air Burners Logos are
 Registered Trademarks of Air Burners, LLC.


Last Updated on May 08, 2008 by Air Burners, LLC.
Contact webmaster for any issues regarding this Web Site